DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

STK551U392A-E 查看數據表(PDF) - ON Semiconductor

零件编号
产品描述 (功能)
生产厂家
STK551U392A-E
ON-Semiconductor
ON Semiconductor ON-Semiconductor
STK551U392A-E Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
STK551U392A-E
Parameter
Symbol
Conditions
Switching Character
Switching time
tON
tOFF
Io = 15 A
Inductive load
Turn-on switching loss
Turn-off switching loss
Total switching loss
Eon
Ic = 8 A,V+ = 300 V,
Eoff
VDD = 15 V, L = 3.9mH
Etot
Tc = 25C
Turn-on switching loss
Turn-off switching loss
Total switching loss
Eon
Ic = 8A, V+ = 300 V,
Eoff
VDD = 15V, L = 3.9mH
Etot
Tc = 100C
Diode reverse recovery energy
Diode reverse recovery time
Erec
Trr
IF = 8A, V+ = 400 V, VDD = 15 V,
L = 3.9mH, Tc = 100C
Reverse bias safe operating
area
Short circuit safe operating area
Allowable offset voltage slew
rate
RBSOA
SCSOA
dv/dt
Io = 30 A, VCE = 450 V
VCE = 400V, Tc = 100C
Between U,V,W to U-,V-,W-
Reference voltage is “VSS” terminal voltage unless otherwise specified.
Test
circuit
Fig.6
Ratings
min
typ
max
0.3
0.6
1.3
-
1.0
1.8
-
170
-
-
210
-
-
380
-
-
220
-
-
380
-
-
600
-
-
12
-
-
54
-
Full square
4
-
-
50
-
50
Unit
s
J
J
J
J
J
J
J
ns
s
V/ns
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be
indicated by the Electrical Characteristics if operated under different conditions.
Notes :
1. When the internal protection circuit operates, a Fault signal is turned ON (When the Fault terminal is low level, Fault signal is ON
state : output form is open DRAIN) but the Fault signal does not latch.After protection operation ends,it returns automatically within
about 18 ms to 80 ms and resumes operation beginning condition. So, after Fault signal detection, set all input signals to OFF (Low)
at once.However, the operation of pre-drive power supply low voltage protection (UVLO : with hysteresis about 0.2 V) is as follows.
Upper side :
The gate is turned off and will return to regular operation when recovering to the normal voltage, but the latch will continue till the
input signal will turn ‘low’.
Lower side :
The gate is turned off and will automatically reset when recovering to normal voltage. It does not depend on input signal voltage.
2. When assembling the IPM on the heat sink with M3 type screw, tightening torque range is 0.6 Nm to 0.9 Nm.
3. The pre-drive low voltage protection is the feature to protect devices when the pre-driver supply voltage falls due to an operating
malfunction.
www.onsemi.com
3

Share Link: 