Si7013-A20
Table 4. Humidity Sensor
1.9 VDD 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.
Parameter
Operating Range1
Accuracy2, 3
Repeatability-Noise
Symbol
Test Condition
Non-condensing
0 – 80% RH
80 – 100% RH
12-bit resolution
11-bit resolution
10-bit resolution
8-bit resolution
Min Typ Max
0
— 100
s
±2
±3
n See Figure 2.
ig — 0.025 —
— 0.05 —
s
0.1
De
0.2
Unit
%RH
%RH
%RH
%RH RMS
%RH RMS
%RH RMS
%RH RMS
Response Time4
1 m/s airflow, with cover
18
τ63%
1 m/s airflow, without cover
17
S
w Drift vs. Temperature
— 0.05 —
%RH/°C
e Hysteresis
Long Term Stability3
±1
— < 0.25 —
%RH
%RH/yr
N Notes:
r 1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading with slow recovery time.
fo 2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See Section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30°C and 30% to 50% RH. May be impacted by dust, vaporized
d solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See Section “4.7. Long
Term Drift/Aging”
Not Recommende 4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
Rev. 1.4