DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

SI7013-A10-YM1R 查看數據表(PDF) - Silicon Laboratories

零件编号
产品描述 (功能)
生产厂家
SI7013-A10-YM1R
Silabs
Silicon Laboratories Silabs
SI7013-A10-YM1R Datasheet PDF : 46 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Si7013-A10
Table 4. Humidity Sensor
1.9 VDD 3.6 V; TA = 30 °C; default conversion time unless otherwise noted.
Parameter
Operating Range1
Accuracy2, 3
Repeatability-Noise
Symbol
Response Time4
Drift vs. Temperature
Hysteresis
Long Term Stability3
τ63%
Test Condition
Non-condensing
0 – 80% RH
80 – 100% RH
12-bit resolution
11-bit resolution
10-bit resolution
8-bit resolution
1 m/s airflow
Min Typ Max
0
100
±2
±3
See Figure 2
— 0.025 —
— 0.05 —
0.1
0.2
18
— 0.05 —
±1
— < 0.25 —
Unit
%RH
%RH
%RH
%RH RMS
%RH RMS
%RH RMS
%RH RMS
S
%RH/°C
%RH
%RH/yr
Notes:
1. Recommended humidity operating range is 20% to 80% RH (non-condensing) over –10 °C to 60 °C. Prolonged
operation beyond these ranges may result in a shift of sensor reading with slow recovery time.
2. Excludes hysteresis, long term drift, and certain other factors and is applicable to non-condensing environments only.
See Section “4.1. Relative Humidity Sensor Accuracy” for more details.
3. Drift due to aging effects at typical room conditions of 30°C and 30% to 50% RH. May be impacted by dust, vaporized
solvents or other contaminants, e.g., out-gassing tapes, adhesives, packaging materials, etc. See Section “4.7. Long
Term Drift/Aging”
4. Response time to a step change in RH. Time for the RH output to change by 63% of the total RH change.
Rev. 1.0