DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MVAC400-48AFD 查看數據表(PDF) - Murata Power Solutions

零件编号
产品描述 (功能)
生产厂家
MVAC400-48AFD
Murata-ps
Murata Power Solutions Murata-ps
MVAC400-48AFD Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
MECHANICAL DIMENSIONS – ALL MODELS
& 
> @
& 
> @
7%
-
3,1
3,1
5(029('
“
“ % 
-
3,1
> @
07*
07*
“
“
MVAC400 Series
400W 3" x 5" High Density AC-DC Power Supply Converter
“
“
$ 
> @
07*
35,0$5<
+($76,1.
127( !
07*
02817,1*6/276
:,'7+  
> @
0$;6&5(:+($'
',$0(7(5 
6(&21'$5<
+($76,1.
127( !
MOUNTING GRID
A
B
4.50 x 2.50 114.30 [4.500] 63.50 [ 2.500]
4.55 x 2.55 115.57 [4.550] 64.77 [ 2.550]
&
>@
>@
-
3,1
-
3,1
-
3,1
-
3,1
J2
6 12
5 11
4 10
39
28
17
J3
21
43
65
87
1-6
+DC_OUT
7-12 +DC_OUT_RTN
1
+5V_AUX
2
PWR_OK
3
+12V_FAN_RTN
4
PS_ON
5 +REMOTE_SENSE
6 -REMOTE_SENSE
7
+12V_FAN
8
+5V_AUX_RTN
$//',0(16,216$5(,100>,1@
“
“
SAFETY CONSIDERATION NOTES:
1. Protective bonding conductor from the end product protective earthing terminal must be tied to TB1. For optimum EMI performance, while maintaining
Class I safety isolation all 4 mounting holes must be tied to the end product protective earthing terminal. To maintain Class II safety isolation mounting
holes MTG1 and MTG2 need to be isolated from protective earth and should use standoffs of non-conductive material.
2. This power supply requires mounting standoffs of minimum 6mm in height. If there is risk of chassis deformation or shorter standoff height isrequired,
an appropriate insulator must be used under the power supply with adequate extension beyond the outline of the power supply. In all cases,the
applicable safety standards must be applied to ensure proper creepage and clearance requirements are met.
3. The primary heatsink is considered a live primary circuit, and should not be touched. It is recommended that the primary heatsink be kept at least
3.5mm from chassis and 7mm from secondary circuits. In all cases, the applicable safety standards must be applied to ensure proper creepage and
clearance requirements are met.
4. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to:
http://www.murata-ps.com/requirements/
5. Used only in non-tropical conditions.
6. Double pole/neutral fusing.
Dimensions: 3.0" x 5.0" x 1.4" (76.2mm x 127mm x 35.6mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS – ALL MODELS
Connector
PIN
Description
Mating Housing
Input Connector J1: 1
Molex 26-62-4030 3
AC Neutral
AC Line
Molex 0009930300
Output Connector J2: 1,2,3,4,5,6
Molex 39-28-1123 7,8,9,10,11,12
+DC_OUT
+DC_OUT_RTN
Molex 0039012125
1
+5V_AUX
2
PWR_OK
3
+12V_FAN_RTN
Output Connector J3: 4
Molex 90130-1108 5
PS_ON
+Remote Sense
Molex 0901420008
6
-Remote Sense
7
+12V_FAN
8
+5V_AUX_RTN
Crimp terminal/pins
Molex 0008500105 (18-24 AWG)
Molex 0008500107 (22-26 AWG)
Molex 0039000038
Molex 0901190109
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating require-
ments and the Life and Safety Critical Application Sales
Policy. Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. (“Murata”) makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the
granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen
the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affiliated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifications are subject
to change without notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support
MVAC400.A11 Page 7 of 7