Typical Link Data
HFBR-0400 Series
Description
The following technical data is
taken from 4 popular links using
the HFBR-0400 series: the 5
MBd link, Ethernet 20 MBd link,
Token Ring 32 MBd link, and the
corresponds to transceiver
solutions combining the HFBR-
0400 series components and
various recommended
transceiver design circuits using
off-the-shelf electrical
components. This data is meant
to be regarded as an example of
typical link performance for a
given design and does not call
out any link limitations. Please
refer to the appropriate
application note given for each
link to obtain more information.
5 MBd Link (HFBR-14xx/24x2)
Link Performance -40 °C to +85 °C unless otherwise specified
Parameter
Symbol Min.
Typ.
Max.
Units
Conditions
Reference
Optical Power Budget
OPB50
4.2
9.6
with 50/125 µm fiber
dB
HFBR-14x4/24x2
Note 1
NA = 0.2
Optical Power Budget
OPB62.5
8.0
15
with 62.5/125 µm fiber
dB
HFBR-14x4/24x2
Note 1
NA = 0.27
Optical Power Budget
OPB100
8.0
15
with 100/140 µm fiber
dB
HFBR-14x2/24x2
Note 1
NA = 0.30
Optical Power Budget
OPB200
12
20
with 200 µm fiber
dB
HFBR-14x2/24x2
Note 1
NA = 0.37
Date Rate Synchronous
dc
5
MBd
Note 2
Asynchronous
dc
2.5
MBd
Note 3,
Fig 7
Propagation Delay
tPLH
72
LOW to HIGH
Propagation Delay
tPHL
46
HIGH to LOW
ns
TA = +25 °C
Figs 6, 7, 8
PR = -21 dBm peak
ns
System Pulse Width
tPLH - tPHL
26
Distortion
ns
Fiber cable length = 1 m
Bit Error Rate
BER
10-9
Data rate <5 Bd
PR > -24 dBm peak
Notes:
1. OPB at TA = -40 to +85 °C, VCC = 5.0 V dc, IF ON = 60 mA. PR = -24 dBm peak.
2. Synchronous data rate limit is based on these assumptions: a) 50% duty factor modulation, e.g., Manchester I or BiPhase Manchester II; b)
continuous data; c) PLL Phase Lock Loop demodulation; d) TTL threshold.
3. Asynchronous data rate limit is based on these assumptions: a) NRZ data; b) arbitrary timing-no duty factor restriction; c) TTL threshold.
10