DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS2482-100 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
DS2482-100
MaximIC
Maxim Integrated MaximIC
DS2482-100 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS2482-100
Single-Channel 1-Wire Master
Function Commands
The DS2482-100 understands eight function com-
mands that fall into four categories: device control, I2C
communication, 1-Wire setup, and 1-Wire communica-
tion. The feedback path to the host is controlled by a
read pointer, which is set automatically by each func-
tion command for the host to efficiently access relevant
information. The host processor sends these com-
mands and applicable parameters as strings of one or
two bytes using the I2C interface. The I2C protocol
requires that each byte be acknowledged by the
receiving party to confirm acceptance or not be
acknowledged to indicate an error condition (invalid
code or parameter) or to end the communication. See
the I2C Interface section for details of the I2C protocol
including acknowledge.
The function commands are as follows:
1) Device Reset
5) 1-Wire Single Bit
2) Set Read Pointer
6) 1-Wire Write Byte
3) Write Configuration
7) 1-Wire Read Byte
4) 1-Wire Reset
8) 1-Wire Triplet
Table 1. Valid Pointer Codes
REGISTER SELECTION
Status Register
Read Data Register
Configuration Register
CODE
F0h
E1h
C3h
Device Reset
Command Code
F0h
Command Parameter
None
Description
Performs a global reset of device state machine logic. Terminates any ongoing 1-Wire
communication.
Typical Use
Device initialization after power-up; reinitialization (reset) as desired.
Restriction
Error Response
Command Duration
1-Wire Activity
Read Pointer Position
Status Bits Affected
Configuration Bits Affected
None (can be executed at any time).
None
Maximum 525ns. Counted from falling SCL edge of the command code acknowledge bit.
Ends maximum 262.5ns after the falling SCL edge of the command code acknowledge bit.
Status Register (for busy polling).
RST set to 1; 1WB, PPD, SD, SBR, TSB, DIR set to 0.
1WS, APU, SPU set to 0.
Set Read Pointer
Command Code
Command Parameter
E1h
Pointer Code (see Table 1)
Description
Sets the read pointer to the specified register. Overwrites the read pointer position of any 1-Wire
communication command in progress.
Typical Use
To prepare reading the result from a 1-Wire Read Byte command; random read access of
registers.
Restriction
None (can be executed at any time).
Error Response
If the pointer code is not valid, the pointer code is not acknowledged and the command is
ignored.
Command Duration
1-Wire Activity
Read Pointer Position
Status Bits Affected
Configuration Bits Affected
None. The read pointer is updated on the rising SCL edge of the pointer code acknowledge bit.
Not affected.
As specified by the pointer code.
None
None
www.maximintegrated.com
Maxim Integrated | 9

Share Link: 