DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PBA300F-5 查看數據表(PDF) - Unspecified

零件编号
产品描述 (功能)
生产厂家
PBA300F-5 Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
AC-DC Power Supplies Enclosed Type
Ordering information
PPBBAA//PPBW
PBA1000F
PB A 1000 F -5 -O
1
2
3
4
5
6
1Series name
R
Recommended EMI/EMC Filter 2Single output
NAC-20-472
3Output wattage
4Universal input
5Output voltage
6Optional *6
C :with Coating
G :Low leakage current
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA1000F-3R3
660
ACIN 100V 3.3V 200A
ACIN 200V*3 3.3V 200A
PBA1000F-5
1000
5V 200A
5V 200A
PBA1000F-7R5
1005
7.5V 134A
7.5V 134A
PBA1000F-12
1056
12V 88A
12V 88A
PBA1000F-15
1050
15V 70A
15V 70A
PBA1000F-24
1056
24V 44A
24V 44(51)A
PBA1000F-36
1044
36V 29A
36V 29A
PBA1000F-48
1056
48V 22A
48V 22A
SPECIFICATIONS
MODEL
PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48
VOLTAGE[V]
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 100V 9typ
ACIN 200V 5typ
13typ
7typ
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 100V 74typ
ACIN 200V 76typ
79typ
81typ
80typ
83typ
82typ
84typ
82typ
84typ
84typ
86typ
84typ
86typ
84typ
86typ
POWER FACTOR
ACIN 100V 0.98typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 10 sec. to re-start)
INRUSH CURRENT[A] ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 10 sec. to re-start)
LEAKAGE CURRENT[mA]
0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
VOLTAGE[V]
3.3
5
7.5
12
15
24
36
48
ACIN 100V 200
200
134
88
70
44
29
22
CURRENT[A]
ACIN 200V*3 200
200
134
88
70
44(51)
29
22
LINE REGULATION[mV]
20max
20max
36max
48max
60max
96max
144max
192max
LOAD REGULATION[mV]
40max
40max
60max
100max
120max
150max
150max
300max
RIPPLE[mVp-p]
0 to +50C*1 80max
-20 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
150max
160max
150max
400max
OUTPUT
RIPPLE NOISE[mVp-p] 0 to +50C*1 120max
-20 - 0C*1 160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
200max
240max
200max
500max
TEMPERATURE REGULATION[mV]
0 to +50C
-20 to +50C
40max
60max
50max
75max
75max
120max
120max
180max
150max
180max
240max
290max
360max
440max
480max
600max
DRIFT[mV]
*2 12max
20max
30max
48max
60max
96max
144max
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100/200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] *4 Vo+0.66 - 1.32 Vo+1.0 - 2.0
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Provided
Vo+1.5 - 3.0
Vo+2.4 - 4.8
Vo+3.0 - 6.0
Vo+4.8 - 9.6
Vo+7.2 - 14.4 Vo+4.8 - 12.0
REMOTE ON/OFF
Provided
INPUT-OUTPUT -RC
ISOLATION INPUT-FG
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
NOISE
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS HARMONIC ATTENUATOR
Complies with IEC61000-3-2 *7
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
150X61X240mm [5.91X2.4X9.45 inches] (without terminal block and screw) (WXHXD) /2.2kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
*7 Please contact us about class C.
* A sound may occur from power supply at pulse loading.
PBA/PBWW--2200

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]