AC-DC Power Supplies Enclosed Type
Ordering information
PPBBAA//PPBW
PBA1500T
PB A 1500 T -5 -O
1
2
3
4
5
6
1Series name
R
Recommended EMI/EMC Filter 2Single output
TAC-10-683
3Output wattage
4Triple input phase
5Output voltage
6Optional *6
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F1 :With Long-Life fan
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA1500T-5
1500
ACIN 200V*3 5V 300A
PBA1500T-12
1500
12V 125A
PBA1500T-24
1680
24V 70(105)A
PBA1500T-48
1680
48V 35A
SPECIFICATIONS
MODEL
PBA1500T-5
PBA1500T-12
PBA1500T-24
PBA1500T-48
VOLTAGE[V]
AC170 - 264 3f (AC100 Please refer to the instruction manual 7. option *5)
CURRENT[A]
ACIN 200V 6typ
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 200V 81typ
84typ
87typ
87typ
POWER FACTOR
ACIN 200V 0.95typ (Io=100%)
INRUSH CURRENT[A] ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
LEAKAGE CURRENT[mA]
1.5max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1, DENAN)
VOLTAGE[V]
5
12
24
48
CURRENT[A]
ACIN 200V*3 300
125
70(105)
35
LINE REGULATION[mV]
20max
48max
96max
192max
LOAD REGULATION[mV]
40max
100max
150max
300max
RIPPLE[mVp-p]
0 to +50C*1 80max
-20 - 0C*1 140max
120max
160max
120max
160max
150max
400max
OUTPUT
RIPPLE NOISE[mVp-p] 0 to +50C*1 120max
-20 - 0C*1 160max
150max
180max
150max
180max
200max
500max
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-20 to +50C 75max
120max
180max
240max
290max
480max
600max
DRIFT[mV]
*2 20max
48max
96max
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ(ACIN 200V, Io=100%) *Start-up time is 500ms typ for less than 1 minute of applying input again from turning off the input voltage.
20typ (ACIN 200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 3.96 - 6.00
8.25 - 13.20
16.50 - 26.40
38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15
12.00 - 12.48
24.00 - 24.96
48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] *4 Vo+1.0 - 2.0
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Provided
Vo+2.4 - 4.8
Vo+4.8 - 9.6
Vo+2.0 - 12.0
REMOTE ON/OFF
Provided
INPUT-OUTPUT -RC
INPUT-FG
ISOLATION
OUTPUT-RC-AUX-FG
OUTPUT-RC -AUX
OPERATING TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
-20 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input)
NOISE
REGULATIONS CONDUCTED NOISE
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional EMI/EMC Filter required for meeting class B
178X61X268mm [7.01X2.4X10.55 inches] (without terminal block and screw) (WXHXD) /3.4kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
Ripple and ripple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual
in detail.
*4 Overvoltage protection circuit to follow to output voltage setting. Standard overvoltage
protection circuit is please contact us for details.
*5 Derating is required.Consult us for details.
*6 Please contact us about safety approvals for the model with option.
* A sound may occur from power supply at pulse loading.