DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HVG-65-54 查看數據表(PDF) - Mean Well Enterprises Co., Ltd.

零件编号
产品描述 (功能)
生产厂家
HVG-65-54
MEANWELL
Mean Well Enterprises Co., Ltd. MEANWELL
HVG-65-54 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
65W Constant Voltage + Constant Current LED Driver
HVG-65 series
SPECIFICATION
MODEL
HVG-65-12 HVG-65-15 HVG-65-20 HVG-65-24 HVG-65-30 HVG-65-36 HVG-65-42 HVG-65-48 HVG-65-54
DC VOLTAGE
12V
CONSTANT CURRENT REGION Note.4 7.2 ~12V
RATED CURRENT
5A
RATED POWER
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
15V
9 ~ 15V
4.3A
64.5W
150mVp-p
20V
12 ~ 20V
3.25A
65W
150mVp-p
24V
14.4 ~ 24V
2.71A
65W
150mVp-p
30V
18 ~ 30V
2.17A
65.1W
200mVp-p
36V
21.6 ~ 36V
1.81A
65.2W
200mVp-p
42V
25.2 ~ 42V
1.55A
65.1W
300mVp-p
48V
28.8 ~ 48V
1.36A
65.3W
300mVp-p
54V
32.4 ~ 54V
1.21A
65.3W
300mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
Adjustable for A-Type only (via the built-in potentiometer)
10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V 22 ~ 27V 27 ~ 33V
CURRENT ADJ. RANGE
Adjustable for A-Type only (via the built-in potentiometer)
3 ~ 5A
2.58 ~ 4.3A 1.95 ~ 3.25A 1.62 ~ 2.71A 1.3 ~ 2.17A
VOLTAGE TOLERANCE Note.3 ±2.0%
±2.0%
±1.0%
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
LOAD REGULATION
±1.5%
±1.5%
±0.5%
±0.5%
±0.5%
SETUP, RISE TIME
500ms, 80ms /230VAC 400ms, 80ms /347VAC, 480VAC
33 ~ 40V 38 ~ 46V 43 ~ 53V 49 ~ 58V
1.08 ~ 1.81A 0.93 ~ 1.55A 0.81 ~ 1.36A 0.72 ~ 1.21A
±1.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
HOLD UP TIME (Typ.)
16ms / 347VAC 30ms / 480VAC
VOLTAGE RANGE
180 ~ 528VAC 254VDC ~ 747VDC
Note.5 (Please refer to "STATIC CHARACTERISTIC" section)
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF0.98/230VAC, PF0.97/277VAC, PF0.97/347VAC, PF0.93/480VAC @full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
INPUT
THD< 20%(@ load60%/230VAC, 277VAC, 347VAC; @ load75%/480VAC)
TOTAL HARMONIC DISTORTION (Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
EFFICIENCY (Typ.)
86.5%
87.5%
88.5%
89%
89%
89.5%
89.5%
90%
90%
AC CURRENT (Typ.)
0.22A / 347VAC 0.18A / 480VAC
INRUSH CURRENT (Typ.)
COLD START 25A(twidth=420μs measured at 50% Ipeak) at 480VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 480VAC
LEAKAGE CURRENT
<0.75mA / 480VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
14.4 ~ 16.8V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V
Shut down o/p voltage with auto-recovery or re-power on to recovery
47 ~ 53V
54 ~ 60V
59 ~ 65V
OVER TEMPERATURE
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
ENVIRONMENT
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
Shut down o/p voltage, recovers automatically after temperature goes down
Tcase=-40 ~ +80(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
Tcase=+80
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/(0 ~ 60)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.0-13, IP65 or IP67 approved
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMC EMISSION
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
Compliance to EN55015, EN61000-3-2 Class C (@ load60%) ; EN61000-3-3, FCC Part 15 Subpart B
OTHERS
NOTE
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV)
MTBF
612.6K hrs min. Telcordia SR-332 (Bellcore) ; 208K hrs min. MIL-HDBK-217F (25)
DIMENSION
189*61.5*36.8mm (L*W*H)
PACKING
0.77Kg; 18pcs/14.9Kg/0.89CUFT
1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Please refer to “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75or less.
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
File Name:HVG-65-SPEC 2016-10-25