Edition 12/2005
Add a Badge
The badges can be programmed by group according to the access level
selected in menu *4. You can program a series of badges then change the
access level in menu *4 and program another series of badges.
1. Enter the master code twice (for the first use the master code default value is
12345). 2 beeps and the orange LED lights on to confirm that you have entered into
the programming mode.
2. Enter *4 and select the access level 01 or 02 or 03 one beep is emitted.
3. Enter the user location (000 to 499). The LED lights off during 1 second and
one beep is emitted.
4. If the LED turns green, present a badge in front of the enrolment reader
(built-in proximity reader or auxiliary reader#1). The LED lights off during 1
second and one beep is emitted.
the LED lights on solid orange to confirm that the badge was programmed.
5. if the LED turns red (badge is already programmed in that user location),
delete the badge or select another user location.
6. to program a badge with the same access level repeat from step 3
7. to program a badge with a different access level repeat from step 2
Press # to exit from the programming mode. 2 beeps confirm that you returned
to reading mode.
4 beeps indicate a data computing error.
Delete or Replace a Badge
1. Enter the master code twice (for the first use the master code default value is 12345).
2 beeps and the orange LED lights on to confirm that you have entered into the
programming mode.
2. Enter *4 and then select the access level 01 or 02 or 03 one beep is emitted.
3. Enter the user location from 000 to 499 to delete. The LED lights off during 1 second and 1 beep is
emitted.
4. If the LED lights on in red it indicates that a badge is programmed at that user location.
5. Press twice to delete the badge. The Led lights off during 1 second and 1 beep is
emitted.
6. The LED lights on in green to confirm that the badge was deleted.
7. Press # to exit from programming.
OR
8. Present a new badge in front of the enrolment unit. The LED lights off during 1 second
and 1 beep is emitted.
9. The LED lights on in orange to confirm that the new badge was programmed.
10. Press # to exit from programming. 2 beeps confirm that you returned to reading mode.
Reset of Master Code and Badges to Factory Default Values
1. Place ST1 jumper on, 2-3 position.
2. The LED flashes in green during 5 seconds. One beep confirms that the master code is restored to
its factory default setting 12345. The LED starts then flashing in red.
3. Remove the jumper from 2-3 position to go back to stand-by mode.
OR
4. Keep the jumper on 2-3 position to delete all the badges from the controller.
5. The red LED flashes during 5 seconds then turns to solid red during the rest of the reset.
6. Once all the badges have been deleted, the LED lights off.
7. Remove the jumper from 2-3 position to go back to the stand-by mode.