IN2411
ELECTRICAL CHARACTERISTICS(Voltages Referenced to GND, TA = -45 to +65°C)
Guaranteed Limits
Symbol
Parameter
Test Conditions
Min Typ Max
Unit
VSI Initiation Supply Voltage See Figure 1
(1)
16.8
21.2
V
ISI
Initiation Supply Current
(1)
1.4
4.2
mA
VSUS Sustaining Voltage (2) See Figure 1
9.5
12.2
V
ISUS
Sustaining Current (2)
No Load VCC=VSUS
0.7
See Figure 1
2.5
mA
VOH High-Level Output
Voltage
VCC=21V, IOH=-15mA,
16.7
Pin 6=6V, Pin 7=GND
21.0
V
VOL Low-Level Output
VCC=21V, IOL=15mA,
-
Voltage
Pin 6=GND, Pin 7=6V
1.8
V
IIN
Maximun Input Leakage Pin 3=6V,Pin 4=GND,
-
Current
(Pin 3) VCC=21V
(Pin 7) Pin 7=6V,Pin 6=GND,
-
VCC=21V
fH1
High Frequency 1
R3=191KΩ,C3=6800pF
461
fH2
High Frequency 2
R3=191KΩ,C3=6800pF
576
fL
Low Frequency
R2=165KΩ,C2=0.47µF
9.0
1.0
µA
1.0
µA
563
Hz
704
Hz
11.0
Hz
Notes:
1. Initiation supply voltage (VSI) is the supply voltage required to start the tone ringer oscillating.
2. Sustaining voltage (VSUS) is the supply voltage required to maintain oscillation.
3