6
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each parameter in isolation,
all other parameters having values within the recommended operating conditions. It should not be assumed that limiting values of more than one
parameter can be applied to the product at the same time. Exposure to the absolute maximum ratings for extended periods can adversely affect
device reliability.
Parameter
Symbol Min. Typ. Max. Unit Reference
Storage Temperature
Supply Voltage
Data Input Voltage
Transmitter Differential Input Voltage
Output Current
Relative Humidity
TS
-40
VCC
-0.5
VI
-0.5
VD
ID
RH
5
+100
°C
7.0
V
1
VCC
V
1.6
V
2
50
mA
95
%
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Case Temperature
Supply Voltage
Power Supply Rejection
Transmitter Data Input Voltage - Low
Transmitter Data Input Voltage - High
Transmitter Differential Input Voltage
Data Output Load
Signal Detect Output Load
Symbol
TA
TC
VCC
PSR
VIL-VCC
VIH-VCC
VD
RDL
RSDL
Min.
0
4.75
-1.810
-1.165
0.3
50
50
Typ.
50
Max.
+70
+90
5.25
-1.475
-0.880
1.6
Unit
°C
°C
V
mVP-P
V
V
V
W
W
Reference
3
4
5
6
6
7
7
Process Compatibility
Parameter
Hand Lead Soldering Temperature/Time
Wave Soldering and Aqueous Wash
Symbol
TSOLD/tSOLD
TSOLD/tSOLD
Min.
Typ. Max. Unit Reference
+260/10 °C/sec.
+260/10 °C/sec.
8
Notes:
1. The transceiver is class 1 eye safe up to VCC = 7 V.
2. This is the maximum voltage that can be applied across the Differential Transmitter Data Inputs without damaging the input
circuit.
3. 2 m/s air flow required.
4. Case temperature measurement referenced to the center-top of the internal metal transmitter shield.
5. Tested with a 50 mVP-P sinusoidal signal in the frequency range from 500 Hz to 1500 kHz on the VCC supply with the
recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
6. Compatible with 10 K, 10 KH, and 100 K ECL and PECL input signals.
7. The outputs are terminated to VCC -2 V.
8. Aqueous wash pressure <110 psi.