3. Any series inductance considerably complicates the added capacitance
therefore try to reduce the inductance seen at the converter’s output. You
may need to add BOTH a cap at the converter end and at the load (effec-
tively creating a Pi filter) for the express purpose of reducing the phase
angle which is seen by the converter’s output loop controller. This tends
to hide (decouple) the inductance from the controller. Make sure your
power conductors are adequate for the current and reduce the distance
to the load as much as possible. Very low noise applications may require
more than one series inductor plus parallel caps.
4. Oscillation or instabilility can occur at several frequencies. For this
reason, you may need both a large electrolytic or tantalum cap (car-
rying most of the capacitance) and a small wideband parallel ceramic
cap (with low internal series inductance). Always remember that inside
real world capacitors are distributed trace inductance (ESL) and series
resistance (ESR). Make sure the input AC impedance is very low before
trying to improve the output.
5. It is challenging to offer a complete set of simple equations in reason-
able closed form for the added output capacitance. Part of the difficulty is
accurately modeling your load environment. Therefore your best success
may be a combination of previous experience and empirical approxima-
tion.
Maximum Current and Temperature Derating Curves
The curves shown below indicate the maximum average output current
available versus the ambient temperature and airflow. All curves are done
approximately at sea level and you should leave an additional margin for
higher altitude operation and possible fan failure. (Remember that fans are
less efficient at higher altitudes). These curves are an average – current
may be greater than these values for brief periods as long as the average
value is not exceeded.
The “natural convection” area of the curve is that portion where self-
heating causes a small induced convective airflow around the converter
without further mechanical forced airflow from a fan. Natural convection
assumes that the converter is mounted with some spacing to adjacent com-
ponents and there are no nearby high temperature parts. Note that such
self-heating will produce an airflow of typically 25 Linear Feet per Minute
(LFM) without a fan. Heat is removed both through the mounting pins and
the surface of the converter.
Many systems include fans however it is not always easy to measure
the airflow adjacent to the DC/DC converter. Simply using the cubic feet
per minute (CFM) rating of the fan is not always helpful since it must be
matched to the volume of the enclosure, the outside ambient temperature,
board spacing, the intake area and total internal power dissipation.
Most PWM controllers, including those on the TWR’s, will tolerate opera-
tion up to about +100 degrees Celsius. If in doubt, attach a thermal sensor
to the package near the output components and measure the surface
temperature after allowing a proper warm-up period. Remember that the
temperature inside the output transistors at full power will be higher than
the surface temperature therefore do not exceed operation past approxi-
mately +100 deg. C on the surface. As a rough indication, any circuit which
you cannot touch briefly with your finger warrants further investigation.
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
It is probably more important in your system that all heat is periodically
removed rather than having very high airflow. Consider having the total
enclosure completely recycled at least several times a minute. Failure to
remove the heat causes heat buildup inside your system and even a small
fan (relative to the heat load) is quite effective. A very rough guide for typi-
cal enclosures is one cubic foot per minute of exhausted airflow per 100
Watts of internal heat dissipation.
Efficiency Curves
These curves indicate the ratio of output power divided by input power
at various input voltages and output currents times 100%. All curves are
measured at +25°C ambient temperature and adequate airflow.