DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NX25F011A 查看數據表(PDF) - NexFlash -> Winbond Electronics

零件编号
产品描述 (功能)
生产厂家
NX25F011A Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
NX25F011A
NX25F041A
Write Configuration Register
The Write Configuration Register command provides
access to the configuration register which stores the
current configuration of the HOLD-R/B pin, read-data
clock edge, write protect range, and alternate oscillator
frequency. The configuration register is non-volatile. Once
set using the Write Configuration Register command, the
contents will maintain even when power is removed.
Because the registers state is stored in non-volatile
memory, there is a finite endurance limit to the number of
times it can be written to. To limit the number of writes, it
is recommended that before writing to the configuration
register it should first be read from using the Read
Configuration Register command. If no change is
required, the Write Configuration Register command can
be skipped. This process will help extend the endurance
of the configuration register bits and eliminate additional
programming busytime.
The Write Configuration Register command sequence
starts with the command byte (8AH) followed by a 16-bit
field that specifies configuration register bit settings.
Although the field is 16-bits long, only bits CF[8:0] are
used. All other upper bits are reserved and must be
clocked using 0 for data. After an additional 16 control
clocks using 0 for data, the command can be completed
by asserting CS high. The device will become busy for a
short time (tWP) while the non-volatile memory cells of the
configuration register are programmed.
Write
Configuration
Register Configuration
Command
Bits*
16 Clocks
SI
8AH
CF[15:0]
0000H
SO
*The CF Register only uses bits [8:0]
Read Status Register
The Read Status Register command provides access to
the status register and its status flags for Ready/Busy
(R/B), SRAM and program buffer transfer operations (TX),
Write Enable/Disable (WE), and Compare Not Equal (CNE)
(Figure 8). The command sequence is similar to the 0
command except that the sector address field S[15:0] and
the byte-address field B[15:0] are replaced by all 0 bits.
After 16 clocks and the Ready/Busy status field RB[15:0]
has been read, an 8-bit Status field ST[7:0] provides the
contents of the Status Register.
Read Status
Register
Command
16 Clocks
SI
83H
0000H
16 Clocks
0000H
16 Clocks
0000H
SO
RB[15:0]
ST[7:0]
Read/Busy Read Status
Status Register Bits
18
NexFlash Technologies, Inc.
PRELIMINARY NXSF014B-0699
06/11/99

Share Link: 