AT Command Summary
General Commands
D
set all to Defaults
E0
Echo Off
E1
Echo On
I
print the ID
L0
Linefeeds Off (default set by pin 7)
L1
Linefeeds On
WS
Warm Start (quick software restart)
Z
reset all
OBD Commands
AL
Allow Long (>7 byte) messages
BD
perform a Buffer Dump
BI
Bypass the Initialization sequence
DP
Describe the current Protocol
DPN Describe the Protocol by Number
H0
Headers Off (default)
H1
Headers On
M0
Memory Off (default set by pin 5)
M1
Memory On
MA
Monitor All
MR hh Monitor for Receiver = hh
MT hh Monitor for Transmitter = hh
NL
Normal Length (7 byte) messages
PC
Protocol Close
R0
Responses Off
R1
Responses On
SH yzz
Set Header
SH xx yy zz Set Header
SP h Set Protocol to h and save it
SP Ah Set Protocol to Auto, h and save it
ST hh Set Timeout to hh x 4 msec
TP h Try Protocol h
TP Ah Try Protocol h with Auto search
ELM327
CAN Specific Commands
CAF1 CAN Automatic Formatting On
CAF0 CAN Automatic Formatting Off
CF hhh set the ID Filter to hhh
CF hh hh hh hh set the ID Filter to hhhhhhhh
CFC1 CAN Flow Control On
CFC0 CAN Flow Control Off
CM hhh set the ID Mask to hhh
CM hh hh hh hh set the ID Mask to hhhhhhhh
CP hh set CAN Priority (only for 29 bit)
CS
show the CAN Status
ISO Specific Commands
IB 10 set the ISO Baud rate to 10400
IB 96 set the ISO Baud rate to 9600
SW hh Set Wakeup interval to hh x 20 msec
WM xx yy zz aa set the Wakeup Message
WM xx yy zz aa bb
WM xx yy zz aa bb cc
Misc. Commands
CV dddd Calibrate the Voltage to dd.dd volts
RV
Read the Voltage
ELM327QSA
Elm Electronics – Circuits for the Hobbyist
www.elmelectronics.com
5 of 5