LM134 Series
ELECTRICAL CHARACTERISTICS
CURRENT SOURCE (Note 2)
SYMBOL
∆ISET
PARAMETER
Set Current Error, V+ = 2.5V
(Note 3)
Ratio of Set Current to
V– Current
VMIN
Minimum Operating Voltage
∆ISET
∆VIN
Average Change in Set Current
with Input Voltage
Temperature Dependence of
Set Current (Note 4)
CS
Effective Shunt Capacitance
CONDITIONS
10µA ≤ ISET ≤ 1mA
1mA < ISET ≤ 5mA
2µA ≤ ISET < 10µA
10µA ≤ ISET ≤ 1mA
1mA ≤ ISET ≤ 5mA
2µA ≤ ISET ≤ 10µA
2µA ≤ ISET ≤ 100µA
100µA < ISET ≤ 1mA
1mA < ISET ≤ 5mA
1.5V ≤ V+ ≤ 5V
2µA ≤ ISET ≤ 1mA
5V ≤ V+ ≤ VMAX (Note 5)
1.5V ≤ V ≤ 5V
1mA < ISET ≤ 5mA
5V ≤ V ≤ VMAX (Note 5)
25µA ≤ ISET ≤ 1mA
LM134
MIN TYP MAX
3
5
8
14
18
23
14
18
23
0.8
0.9
1.0
0.02 0.05
0.01 0.03
0.03
0.02
0.96
1.04
15
LM334
MIN TYP MAX UNITS
6
%
8
%
12
%
14
18
26
14
18
26
0.8
V
0.9
V
1.0
V
0.02
0.1
%/V
0.01 0.05
%/V
0.03
%/V
0.02
%/V
0.96
1.04
15
pF
TEMPERATURE SENSOR (Note 2)
SYMBOL
∆ISET
PARAMETER
Set Current Error, V+ = 2.5V
(Note 3)
Equivalent Temperature Error
CONDITIONS
100µA ≤ ISET ≤ 1mA
Tj = 25°C
Ratio of Set Current to
V– Current
100µA ≤ ISET ≤ 1mA
VMIN
∆ISET
∆VIN
Minimum Operating Voltage
Average Change in Set Current
with Input Voltage
100µA ≤ ISET ≤ 1mA
1.5V ≤ V+ ≤ 5V
100µA ≤ ISET ≤ 1mA
5V ≤ V+ ≤ 30V
Temperature Dependence of
Set Current (Note 4)
100µA ≤ ISET ≤ 1mA
Equivalent Slope Error
CS
Effective Shunt Capacitance
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: Unless otherwise specified, tests are performed at Tj = 25°C with
pulse testing so that junction temperature does not change during test.
Note 3: Set current is the current flowing into the V+ pin. It is determined
by the following formula: ISET = 67.7mV/RSET (at 25°C). Set current error
LM134-3,LM234-3
MIN TYP MAX
±1
LM134-6, LM234-6
MIN TYP MAX
±2
UNITS
%
±3
±6
°C
14
18
26
14
18
26
0.9
0.02 0.05
0.9
V
0.02
0.1
%/V
0.01 0.03
0.01 0.05
%/V
0.98
1.02 0.97
1.03
±2
±3
%
15
15
pF
is expressed as a percent deviation from this amount. ISET increases at
0.336%/°C at Tj = 25°C.
Note 4: ISET is nominally directly proportional to absolute temperature
(°K). ISET at any temperature can be calculated from: ISET = IO (T/TO)
where IO is ISET measured at TO (°K).
Note 5: VMAX = 40V for LM134 and 30V for other grades.
3