2.6.Power Supply ON/OFF Sequence
2.6.1.ON Sequence
SIGNAL
VCC
SIGNAL
VADJ
VEE
DISPOFF
0≦t
0≦t
0≦t
LEVEL
VCC
VSS
VCC
VSS
VCC
VSS
VADJ
VEE
VCC
VSS
2.6.2.OFF Sequence
LEVEL
VCC
VSS
VCC
VSS
VCC
VSS
VADJ
VEE
VCC
VSS
0≦t
0≦t
0≦t
SIGNAL
VCC
SIGNAL
VADJ
VEE
DISPOFF
Please maintain the above sequence when turning on and off the power supply of the module.
If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is
unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD
module.
DMF-51026NY-LY (AB) No.2000-0178
OPTREX CORPORATION
OPTREX
Page 6/18