DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FSPYC260F 查看數據表(PDF) - Intersil

零件编号
产品描述 (功能)
生产厂家
FSPYC260F Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
FSPYC260R, FSPYC260F
Test Circuits and Waveforms (Continued)
VGS = 12V
0V
VDD
RL
VDS
DUT
RGS
VDS
tON
td(ON)
tr
90%
10%
VGS
10%
50%
PULSE WIDTH
tOFF
td(OFF)
tf
90%
10%
90%
50%
FIGURE 13. RESISTIVE SWITCHING TEST CIRCUIT
FIGURE 14. RESISTIVE SWITCHING WAVEFORMS
Screening Information
Screening is performed in accordance with the latest revision in effect of MIL-S-19500, (Screening Information Table).
Delta Tests and Limits (JANTXV Equivalent, JANS Equivalent) TC = 25oC, Unless Otherwise Specified
PARAMETER
SYMBOL
TEST CONDITIONS
MAX
Gate to Source Leakage Current
Zero Gate Voltage Drain Current
Drain to Source On Resistance
Gate Threshold Voltage
NOTES:
IGSS
IDSS
rDS(ON)
VGS(TH)
VGS = ±30V
VDS = 80% Rated Value
TC = 25oC at Rated ID
ID = 1.0mA
±20 (Note 7)
±25 (Note 7)
±20% (Note 8)
±20% (Note 8)
7. Or 100% of Initial Reading (whichever is greater).
8. Of Initial Reading.
UNITS
nA
µA
V
Screening Information
TEST
JANTXV EQUIVALENT
Unclamped Inductive Switching
Thermal Response
Gate Stress
Pind
VGS(PEAK) = 20V, L = 0.1mH; Limit = 110A
tH = 10ms; VH = 25V; IH = 4A; LIMIT = 55mV
VGS = 45V, t = 250µs
Optional
Pre Burn-In Tests (Note 9)
MIL-S-19500 Group A,
Subgroup 2 (All Static Tests at 25oC)
Steady State Gate
Bias (Gate Stress)
Interim Electrical Tests (Note 9)
MIL-STD-750, Method 1042, Condition B
VGS = 80% of Rated Value,
TA = 150oC, Time = 48 hours
All Delta Parameters Listed in the Delta Tests
and Limits Table
Steady State Reverse
Bias (Drain Stress)
PDA
MIL-STD-750, Method 1042, Condition A
VDS
TA =
= 80% of Rated Value,
150oC, Time = 160 hours
10%
Final Electrical Tests (Note 9)
MIL-S-19500, Group A, Subgroup 2
NOTE:
9. Test limits are identical pre and post burn-in.
JANS EQUIVALENT
VGS(PEAK) = 20V, L = 0.1mH; Limit = 110A
tH = 10ms; VH = 25V; IH = 4A; LIMIT = 55mV
VGS = 45V, t = 250µs
Required
MIL-S-19500 Group A,
Subgroup 2 (All Static Tests at 25oC)
MIL-STD-750, Method 1042, Condition B
VGS = 80% of Rated Value,
TA = 150oC, Time = 48 hours
All Delta Parameters Listed in the Delta Tests
and Limits Table
MIL-STD-750, Method 1042, Condition A
VDS
TA =
= 80% of Rated Value,
150oC, Time = 240 hours
5%
MIL-S-19500, Group A, Subgroups 2 and 3
Additional Tests
PARAMETER
Safe Operating Area
Thermal Impedance
SYMBOL
SOA
VSD
TEST CONDITIONS
VDS = 160V, t = 10ms
tH = 500ms; VH =20V; IH = 4A
HEAT SINK REQUIRED
MAX
1.25
115
UNITS
A
mV
6

Share Link: 