Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM200CBS060
Intellimod™ Module
MAXISS Series™, Multi AXIS Servo IPM
200 Amperes/600 Volts
Thermal Characteristics
Characteristic
Junction to Case Thermal Resistance
Contact Thermal Resistance
Symbol
Rth(j-c´)Q
Rth(j-c´)F
Rth(c-f)
*TC measured point is just under the chips.
**If you use this value, Rth(f-a) should be mesured just under the chips.
Condition
Min.
Each IGBT*
—
Each FWDi*
—
Case to Fin Per Module,
—
Thermal Grease Applied
Recommended Conditions for Use
Characteristic
Symbol
Condition
Supply Voltage
VCC
Applied across P-N Terminals
Control Supply Voltage***
VD
Applied between VUP1-VUPC,
VVP1-VVPC, VWP1-VWPC, VN1-VNC
Input ON Voltage
VCIN(on)
Applied between UP-VUPC, VP-VVPC,
Input OFF Voltage
VCIN(off)
WP-VWPC, UN, VN, WN-VNC
PWM Input Frequency
fPWM
Using Application Circuit
Minimum Dead Time
tDEAD
Input Signal
***With ripple satisfying the following conditions: dv/dt ≤ ±5v/µs, Variation ≤ 2V peak to peak.
Typ. Max. Units
—
0.13** °C/Watt
—
0.21** °C/Watt
—
0.025 °C/Watt
Value
≤ 400
15 ± 1.5
Units
Volts
Volts
≤ 0.8
≥ 4.0
≤ 20
≥ 2.5
Volts
Volts
kHz
µS
4