Class 2 Fax Commands (continued)
Error
Code
70
71
72
73
74
90
91
93
94
100
101
102
103
Disconnect Cause
Unspecified phae B error
Receive Response Error
Command received error
T.30 time out, expected page not received
T.30 time out after end of messsage received
Unspecified Phase C Error
Missing End of line after 5 seconds
Receive Buffer overflow
Bad check sum of frame
Receive Phase D errors
Invalid response received
Invalid command received
Unable to continue after page interrupt
+FDCS? - Current Session Results
+FDIS =VR, BR, WD, LN, DF, ED, BF, ST - Set
Current Sessions Capabilities Parameters
+FDR - Begin/Continue Phase C Receive Data
+FDT - Data Transmission
+FET=<ppm> - Transmit Page Punctuation
+FK - Terminate Session
+FLID<local ID>= - Local ID String
+FPHCTO <value>- Phase C Time Out
XE1414 S-Register Summary
Register Range Units Description
Default
S0
0-255
rings Number of rings before intiating automatic answer sequence
000
S1
0-255
rings Count number of incoming rings
000
S2
0-127
-
ASCII Escape character
043
S3
0-127
-
ASCII Carriage return character
013
S4
0-127
-
ASCII Line feed character
010
S5
0-32,127
-
ASCII Backspace character
008
S6
2-255
sec Wait for Dial tone before Blind Dialing
002
S7
1-60
sec Wait time to detect remote carrier
060
S8
0-255
sec Duration of pause created by comma in the command string
002
S9
1-255
0.1 sec Duration of carrier required for recognition as valid Carrier
006
S10
1-255
0.1 sec Delay from loss of carrier to hang up
014
S11
50-255
msec DTMF dialing speed
095
S12
0-255
0.02 sec TIES Escape Code Time Limit
050
S18
0-255
sec Duration of internal Modem tests.
000
S24
Bit Mapped
-
Sleep Mode timer
010
S30
0-255
10msec Duration of inactivity on TXD & RXD before automatic Disconnect 000
S32
0-255
-
ASCII XON Character for in-band Flow Control
017
S33
0-255
-
ASCII XOFF Character for in-band Flow Control
019
S37 Bit Mapped
-
Maximum Link Speed
000
S46
136/138
-
Data Compression Control
138
S48
0,7,128
-
V.42 Negotiations
007