CPC1945Y
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Package Dissipation
PD
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
(10 Seconds Max.)
DIP Package
1 Derate Linearly 1.33 mW/˚C
2 Derate Linearly 16.6 mW/˚C
Min Typ Max Units
-
- 1501 mW
-
- 50 mA
-
-1 A
-
-5 V
-
- 16002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
-
- +260 °C
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Electrical Characteristics
Parameter
Conditions
Symbol Min
Typ
Output Characteristics @ 25°C
Operating Voltage Range
Peak Blocking Voltage
Load Current (Continuous)
Non-repetitive Single Cycle
Surge Current
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise3
VT
-
VL=120VAC
-
VDRM
IL=1.0A
20
-
VDRM
-
IL
0.005
-
ITSM
-
-
ILEAK
-
-
-
-
dv/dt 500
-
Switching Speeds
Turn-on
Turn-off
Zero-Cross Turn-On Voltage
Operating Frequency1
IF=5 mA
IF=5 mA
TON
-
-
TOFF
-
-
1st half cycle
-
2
Sub. half cycle
-
-
-
20
-
Load Power Factor for
Guaranteed Turn-On2
-
PF
0.25
-
Capacitance
Input to Output
-
-
-
3
Input Characteristics @ 25°C
Input Control Current
For Normal Environment
For High Noise Environment
Input Voltage Drop
Input Drop-out Voltage
-
-
IF=5mA
-
IF
5
-
IF
10
-
VF
0.9
1.2
0.8
-
Reverse Input Current
1 Zero cross 1st 1/2 cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM Standard RS-443.
VR=5V
IR
-
-
Max
Units
120
VRMS
400
V
1.0
IARMS
10
A
1
mA
1.6
VRMS
-
V/µS
0.5
Cycles
0.5
Cycles
10
V
1
V
400
Hz
-
-
-
pF
50
mA
100
mA
1.4
V
-
V
10
uA
2