FSYC360D, FSYC360R
Performance Curves Unless Otherwise Specified
LET = 26MeV/mg/cm2, RANGE = 43µ
LET = 37MeV/mg/cm2, RANGE = 36µ
500
FLUENCE = 1E5 IONS/cm2 (TYPICAL)
400
300
200
100
TEMP = 25oC
0
0
-5
-10
-15
-20
-25
VGS (V)
FIGURE 1. SINGLE EVENT EFFECTS SAFE OPERATING AREA
26
20
10
0
-50
0
50
100
150
TC, CASE TEMPERATURE (oC)
FIGURE 3. MAXIMUM CONTINUOUS DRAIN CURRENT vs
TEMPERATURE
1E-3
1E-4
1E-5
1E-6
ILM = 10A
30A
100A
300A
1E-7
10
30
100
300
DRAIN SUPPLY (V)
1000
FIGURE 2. TYPICAL DRAIN INDUCTANCE REQUIRED TO
LIMIT GAMMA DOT CURRENT TO IAS
TC = 25oC
100
10
1
0.1
1
100µs
OPERATION IN THIS
AREA MAY BE
LIMITED BY rDS(ON)
1ms
10ms
10
100
VDS, DRAIN-TO-SOURCE VOLTAGE (V)
1000
FIGURE 4. FORWARD BIAS SAFE OPERATING AREA
12V
QGS
VG
QG
QGD
2.5
PULSE DURATION = 250µs, VGS = 12V, ID = 13A
2.0
1.5
1.0
0.5
CHARGE
FIGURE 5. BASIC GATE CHARGE WAVEFORM
0.0
-80
-40
0
40
80
120
160
TJ, JUNCTION TEMPERATURE (oC)
FIGURE 6. TYPICAL NORMALIZED rDS(ON) vs JUNCTION
TEMPERATURE
4