FSYC360D, FSYC360R
Test Circuits and Waveforms (Continued)
VDD
VGS = 12V
0V
RGS
RL
VDS
DUT
FIGURE 11. RESISTIVE SWITCHING TEST CIRCUIT
VDS
tON
td(ON)
tr
90%
tOFF
td(OFF)
tf
90%
10%
10%
VGS
10%
50%
PULSE WIDTH
90%
50%
FIGURE 12. RESISTIVE SWITCHING WAVEFORMS
Screening Information
Screening is performed in accordance with the latest revision in effect of MIL-S-19500, (Screening Information Table).
Delta Tests and Limits (JANTXV Equivalent, JANS Equivalent) TC = 25oC, Unless Otherwise Specified
PARAMETER
SYMBOL
TEST CONDITIONS
MAX
Gate to Source Leakage Current
IGSS
Zero Gate Voltage Drain Current
IDSS
Drain to Source On Resistance
rDS(ON)
Gate Threshold Voltage
VGS(TH)
NOTES:
7. Or 100% of Initial Reading (whichever is greater).
8. Of Initial Reading.
VGS = ±20V
VDS = 80% Rated Value
TC = 25oC at Rated ID
ID = 1.0mA
±20 (Note 7)
±25 (Note 7)
±20% (Note 8)
±20% (Note 8)
UNITS
nA
µA
V
Screening Information
TEST
Unclamped Inductive Switching
Thermal Response
Gate Stress
Pind
Pre Burn-In Tests (Note 9)
Steady State Gate
Bias (Gate Stress)
Interim Electrical Tests (Note 9)
Steady State Reverse
Bias (Drain Stress)
PDA
Final Electrical Tests (Note 9)
JANTXV EQUIVALENT
VGS(PEAK) = 15V, L = 0.1mH, Limit = 63A
tH = 10ms; VH = 25V; IH = 4A; Limit = 55mV
VGS = 30V, t = 250µs
Optional
MIL-S-19500 Group A,
Subgroup 2 (All Static Tests at 25oC)
MIL-STD-750, Method 1042, Condition B
VGS = 80% of Rated Value,
TA = 150oC, Time = 48 hours
All Delta Parameters Listed in the Delta Tests
and Limits Table
MIL-STD-750, Method 1042, Condition A
VDS
TA =
= 80% of Rated Value,
150oC, Time = 160 hours
10%
MIL-S-19500, Group A, Subgroup 2
NOTE:
9. Test limits are identical pre and post burn-in.
JANS EQUIVALENT
VGS(PEAK) = 15V, L = 0.1mH, Limit = 63A
tH = 10ms; VH = 25V; IH = 4A; Limit = 55mV
VGS = 30V, t = 250µs
Required
MIL-S-19500 Group A,
Subgroup 2 (All Static Tests at 25oC)
MIL-STD-750, Method 1042, Condition B
VGS = 80% of Rated Value,
TA = 150oC, Time = 48 hours
All Delta Parameters Listed in the Delta Tests
and Limits Table
MIL-STD-750, Method 1042, Condition A
VDS
TA =
= 80% of Rated Value,
150oC, Time = 240 hours
5%
MIL-S-19500, Group A,
Subgroups 2 and 3
6