MC-4532CC726
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Operating current
Symbol
ICC1 Burst length = 1
Test condition
Grade MIN. MAX. Unit Notes
/CAS latency = 2 -A80
1,170 mA 1
tRC tRC(MIN.), IO = 0 mA
-A10
1,170
/CAS latency = 3 -A80
1,170
-A10
1,170
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
18 mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
18
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
non power down mode
Input signals are changed one time during 30 ns.
360 mA
ICC2NS CKE VIH(MIN.), tCK =
108
Input signals are stable.
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
90 mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
72
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
450 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
Operating current
ICC4 tCK tCK(MIN.)
/CAS latency = 2 -A80
(Burst mode)
IO = 0 mA
-A10
/CAS latency = 3 -A80
-A10
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2 -A80
-A10
/CAS latency = 3 -A80
-A10
360
1,350 mA 2
1,125
1,575
1,395
2,340 mA 3
2,340
2,340
2,340
Self refresh current
ICC6 CKE 0.2 V
36 mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
– 18 + 18 µA
Input leakage current (CKE1)
–500 +500 µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
– 3 + 3 µA
High level output voltage
VOH IO = – 4.0 mA
2.4
V
Low level output voltage
VOL IO = + 4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
6
Data Sheet M13680EJ5V0DS00