DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CXA3268AR 查看數據表(PDF) - Sony Semiconductor

零件编号
产品描述 (功能)
生产厂家
CXA3268AR Datasheet PDF : 42 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CXA3268AR
Electrical Characteristics
AC Characteristics
Unless otherwise specified, Settings 1 and 2, the serial data initial settings, and the following setting conditions
are required.
Ta = 25°C, VCC1 = 3.0V, VCC2 = VCC3 = 12V, GND1/2/3 = 0V, VSS = 0V, SW2 = ON, SW4 = ON,
SW32/34/36 = OFF, no video input, SG1 input to TP5
Note: Serial data values in the table are HEX notation.
Item
Symbol
Serial data
setting (HEX)
Measurement conditions
Min. Typ. Max. Unit
Maximum gain
between input and
output
Y/color difference
GMAX
CONT FFh
Input SG2 (50mVp-p) to TP71 and
measure the output amplitude at TP36.
29 32 34 dB
Maximum gain
between input and
output
RGB
GRGBMAX
CONT FFh
MODE 00h
Input SG2 (50mVp-p) to TP71 and
measure the output amplitude at TP36.
26 29 31 dB
Amount of contrast
attenuation
Gcon
Assume the output amplitude at TP36 when
CONT 00h SG2 (0.5Vp-p) is input to TP71 as GMIN. 25 30
gcon = GMAX – GMIN
dB
Inverted and
non-inverted gain
difference
GINV
Assume the inverted output amplitude at
TP36 when SG2 (0.35Vp-p) is input to TP71
CONT 2Fh as Vinv, and the non-inverted output
amplitude as Vninv.
ginv = 20 log (Vninv/Vinv)
±0.3 dB
Gain difference
between R, G and
B
Input SG2 (0.35Vp-p) to TP71 (TP70, TP72),
GRGB1 CONT 2Fh measure the non-inverted output amplitude
at TP32, TP34 and TP36, and obtain the
GRGB2
MODE 00h
CONT 2Fh
maximum and minimum difference between
these values.
0.6
dB
0.6
Sub-contrast
variable amount
Sub-bright
variable amount
Black limiter
variable amount
GSC1
GSC2
VSB1
VSB2
VBL1
VBL2
Set CONT = 26h, input SG2 (0.35Vp-p) to
SUB-CONT TP71, and assume the non-inverted output
00h amplitude at TP32 and TP34 when SUB-
CONT R/B = 9Ah, 00h and FFh as V1, V2
SUB-CONT
FFh
and V3, respectively.
Gsc1 = 20 log (V3/V1)
Gsc2 = 20 log (V2/V1)
–5.5 –4.5
dB
2.0 2.7
SUB-BRT
R, B 00h
SUB-BRT
R, B FFh
Set U-BRT = 1Ah and measure the non-
inverted level at TP32 and TP34 relative to
the non-inverted black level at TP36 when
SUB-BRT R/B = FFh and 00h.
–1.5 –1.0
V
0.8 1.2
BLK-LIM
00h
Set U-BRT = FFh, measure the inverted and
non-inverted black limit level at TP36 when ±1.6 ±2.1 ±2.7
BLK-LIM = 00h and 1Fh, and assume the
V
BLK-LIM difference from the output DC voltage as
1Fh VBL1 and VBL2, respectively.
±4.7 ±5.1 ±5.4
– 14 –

Share Link: 