DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

CXA3268AR 查看數據表(PDF) - Sony Semiconductor

零件编号
产品描述 (功能)
生产厂家
CXA3268AR Datasheet PDF : 42 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CXA3268AR
Item
Symbol
Serial data
setting (HEX)
Measurement conditions
Min. Typ. Max. Unit
B-Y/
R-Y
Matrix amplitude G-Y/
ratio
R-Y
G-Y/
B-Y
fc1
LPF characteristics
fc2
fo1
Trap
characteristics
fo2
Assume the TP34 output when SG4 (0.1Vp-p)
is input to TP72 as RR, the TP32 amplitude 0.85 1.00 1.15
when SG4 (0.1Vp-p) is input to TP70 as BB,
CONT 63h the TP34 amplitude when SG5 (0.1Vp-p) is
COLOR input to TP72 as RG, and the TP32 amplitude 0.41 0.51 0.61
6Fh when SG5 (0.1Vp-p) is input to TP70 as BG.
B-Y/R-Y = RR/BB,
G-Y/R-Y = RG/RR,
0.15 0.19 0.23
G-Y/B-Y = BG/BB
LPF 01h Input SG3 to TP71 and measure the
MODE 00h frequency which results in –3dB relative to
LPF 07h the TP36 amplitude at 100kHz when LPF =
MODE 00h 01h and 07h.
2.0 2.5
MHz
5.0 6.4
Set U-BRT = 30h, CONT = DFh, input SG7
MODE 00h (13.5MHz) to TP70, TP71 and TP72, and
–20 –27
measure the amount by which the output is
attenuated when FILTER = 01h relative to
FILTER = 00h. Similarly, input SG7 (14.5MHz)
dB
MODE 00h
to TP70, TP71 and TP72, and measure the
amount by which the output is attenuated
–20 –27
when FILTER = 02h relative to FILTER = 00h.
Frequency
response
f RGB
Set SW32, SW34 and SW36 = ON, input SG3
MODE 00h
to TP70, TP71 and TP72, and measure the
frequency which results in –3dB relative to the
5.5
TP32, TP34 and TP36 amplitude at 100kHz.
MHz
REF adjustment
range
VREF1
VREF2
REF 00h Measure the REF pin
output voltage when
REF 07h REF = 00h and 07h.
1.20 1.35 1.50
Output current
1.5mA, sink only
V
1.90 2.05 2.20
DA adjustment
range
VDA1
VDA2
Internal DAC
differential
SDL
non-linearity error
Internal DAC
non-linearity error
SL
∆γ1
Gamma
characteristics
∆γ2
H FIL gain
Ghfil
DA 00h Measure the DA output
Output current
1.0mA
voltage when DA = 00h
DA 07h and 07h.
Output current
–1.0mA
2.7
0.3
V
Measure under the measurement conditions
for each adjustment range.
–1.5
1.5 LSB
Measure under the measurement conditions
for each adjustment range.
–2.0
2.0 LSB
Input SG2 (0.35mVp-p) to TP71 and measure
the amplitude at TP32, TP34 and TP36.
12 14 16
Assume the output amplitude when GAMMA1
CONT 41h = FFh as V1, when GAMMA1 = 3Fh as V2,
dB
and when GAMMA1 = GAMMA2 = 3Fh as V3.
∆γ1 = 20 log (V1/V2)
12 14 16
∆γ2 = 20 log (V3/V2)
Input SG6 to TP69 and measure the output
amplitude at TP2.
15.0 17.0
dB
– 16 –

Share Link: 