HCPL-1930, HCPL-1931, HCPL-193K,
5962-89572 1
Dual-Channel Line Receiver Hermetically Sealed
Optocoupler
Data Sheet
Description
The HCPL-193x devices are dual-channel, hermetically sealed,
high CMR, line receiver optocouplers. The products are capable
of operation and storage over the full military temperature
range and can be purchased as either a commercial product or
with full MIL-PRF-38534 Class Level H or K testing, or from the
DLA Standard Microcircuit Drawing (SMD) 5962-89572. This
16-pin DIP may be purchased with a variety of lead bend and
plating options. See Selection Guide — Lead Configuration
Options for details. Standard Microcircuit Drawing (SMD) parts
are available for each lead style.
CAUTION
It is advised that normal static precautions be
taken in handling and assembly of this
component to prevent damage and/or
degradation which may be induced by ESD.
Features
Dual marked with device part number and DLA Standard
Microcircuit Drawing (SMD)
Manufactured and tested on a MIL-PRF-38534 certified line
QML-38534, Class H and Class K
Hermetically sealed 16-pin dual in-line package
Performance guaranteed over full military temperature
range: –55° C to +125° C
High speed: 10 Mb/s
Accepts a broad range of drive conditions
Adaptive line termination included
Internal shield provides excellent common mode rejection
External base lead allows LED Peaking and LED current
adjustment
1500 Vdc withstand test voltage
High radiation immunity
HCPL-2602 function compatibility
Reliability data available
Applications
Military and space
High reliability systems
Isolated line receiver
Simplex/multiplex data transmission
Computer-peripheral interface
Microprocessor system interface
Harsh environmental environments
Digital isolation for A/D, D/A conversion
Current sensing
Instrument input/output isolation
Ground loop elimination
Pulse transformer replacement
1. See Selection Guide — Lead Configuration Options for available