HER1601PT THRU HER1608PT
GLASS PASSIVATED HIGH EFFICIENCY RECTIFIER
REVERSE VOLTAGE:
50 to 1000 VOLTS
FORWARD CURRENT:
16.0 AMPERE
FEATURES
· Plastic package has Underwriters Laboratory
Flammability Classification 94V-O ctilizing
Flame Retardant Epoxy Molding Compound.
· Dual rectifier construction, positive center-tap
· Low forward voltage, high current capability
· Low thermal resistance
· Ultra fast recovery times, high voltage.
· Low power loss, high efficiency
MECHANICAL DATA
Case: Molded plastic, TO-3P/TO-247AD
Epoxy: UL 94V-O rate flame retardant
Terminals: Leads solderable per MIL-STD-202
method 208 guaranteed
Polarity: As marked
Mounting position: Any
Weight: 0.2ounce, 5.6gram
TO-3P/TO-247AD
(25.4) 1.0
MIN
.034 (.86)
.028 (.71)
(5.2) .205
(4.1) .160
(25.4) 1.0
MIN
.107 (2.7)
.080 (2.0)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Ratings at 25ambient temperature unless otherwise specified.
Single phase, half wave, 60HZ, resistive or inductive load.
For capacitive load, derate current by 20%.
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at TC=100
Peak Forward Surge Current,
8.3ms single half-sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage at 8.0A and TA=25
Maximum Reverse Current
at Rated DC Blocking Voltage
at TA=25
TA=125
Typical Junction Capacitance (Note 1)
Maximum Reverse Recovery Time (Note 2)
Operating and Storage Temperature Range
Symbols HER1601PT HER1602PT HER1603PT HER1604PT HER1605PT HER1606PT HER1607PT HER1608PT
VRRM
50
100 200 300 400 600 800 1000
VRMS
35
70 140 210 280 420 560 700
VDC
50 100 200 300 400 600 800 1000
Units
Volts
Volts
Volts
I(AV)
16.0
Amp
IFSM
VF
IR
CJ
TRR
TJTstg
1.0
85
50
200
1.3
10.0
250
-55 to +150
Amp
1.7
Volts
uAmp
60
pF
80
nS
NOTES:
1- Measured at 1 MHZ and applied reverse voltage of 4.0 VDC.
2- Reverse Recovery Test ConditionsIF=.5AIR=1AIRR=.25A.