B32671P ... B32673P
Power Factor Correction
Maximum AC voltage (VRMS), current (IRMS) vs. frequency and temperature for TA > 100 ºC
The graphs described in the previous section for the permissible AC voltage (VRMS) or current
(IRMS) vs. frequency are given for a maximum ambient temperature TA ≤100 ºC. In case of higher
ambient temperatures (TA), the self-heating (∆T) of the component must be reduced to avoid that
temperature of the component (Top= TA + ∆T) reaches values above maximum operating
temperature.The factor FT shall be applied in the following way:
And FT is given by the following curve:
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 18