FEELING
TECHNOLOGY
FS177N
Recommended Operating Conditions
Parameter
Symbol
Conditions
Supply Voltage
VDD
-
Operating Temperature Range
TA
-
Values
Unit
Min.
Typ.
Max.
3.0
28
V
-40
150
℃
Electrical Characteristics VDD=12.0V, TA=25℃ (unless otherwise specified)
Parameter
Symbol
Conditions
Min.
Values
Typ.
Max.
Average Supply Current(no load)
IDD
-
3.5
10
Output Saturation Voltage
VSAT
Iout= 20mA
165
200
Output Rise time
tr
RL=500Ω, CL=20pF(Figure 7)
0.2
-
0.75
Output Fall time
tf
RL=500Ω, CL=20pF(Figure 7)
20
-
150
Unit
mA
mV
µs
ns
Magnetic Characteristics
Parameter
Operate Points
Release Points
Hysteresis
Symbol
BOP
BRP
BHYST
Conditions
Values
Unit
Min.
Typ.
Max.
+140
-
-
G
-
-
+60
G
30
-
120
G
Hysteresis Characteristics
Vout
Vsat
-S -S 0 +N +N
B (Magnetic)
Magnetic Flux Density in Gauss
Figure.6
Rev2.0 Apr. 23, 2012
P.4