EVERLIGHT ELECTRONICS CO.,LTD.
IRM-27xx SERIES
Reliability Test Item And Condition
The reliability of products shall be satisfied with items listed below.
Confidence level:90%
LTPD:10%
Test Items
Test Conditions
Temperature cycle
1 cycle -40℃
+100℃
(15min)(5min)(15min)
300 cycle test
Temp: +100℃
High temperature test Vcc:6V
1000hrs
Low temperature
storage
Temp: -40℃
1000hrs
High temperature
High humidity
Ta: 85℃,RH:85%
1000hrs
Failure Judgement Samples(n)
Criteria
Defective(c)
n=22,c=0
L0≦ L×0.8
L45≦ L×0.8
n=22,c=0
L: Lower s
pecification limit
n=22,c=0
n=22,c=0
Solder heat
Temp: 260±5℃ 10sec
4mm From the bottom of the package.
n=22,c=0
Everlight Electronics Co., Ltd.
Device No:SZDMO-027-025
http:\\www.everlight.com
Prepared date:5-Apr-2007
Rev 1
Page: 9 of 10
Prepared by: Huayan.Peng