NCM6 Series
Isolated 6W Wide Input Single & Dual Output DC/DC Converters
APPLICATION NOTES
Output Capacitance and start-up times
The NCM6 series does not require output capacitors to meet datasheet specification. To meet datasheet specification, output capacitance should not exceed:
Part No.
NCM6D0505C
NCM6D0512C
NCM6D0515C
NCM6S0503C
NCM6S0505C
NCM6S0512C
NCM6S0515C
NCM6D1205C
NCM6D1212C
NCM6D1215C
NCM6S1203C
NCM6S1205C
NCM6S1212C
NCM6S1215C
NCM6D4805C
NCM6D4812C
NCM6D4815C
NCM6S4803C
NCM6S4805C
NCM6S4812C
NCM6S4815C
Maximun Load Capacitance (per output)
μF
220
100
100
470
220
100
100
220
100
100
470
220
100
100
220
100
100
470
220
100
100
Start-up times
ms
6
12
18
4
7
12
17
5
12
17
2
6
14
17
10
40
60
2
5
15
20
Control Pin
This provides an OFF function which puts the converter into a low power mode when >3V is applied to the pin. When the control pin is left un-connected or less than 1V the
converter is ON
Minimum Load
The minimum load to meet full datasheet specification is 10% of the full rated load across the specified input voltage range.
Between 0% and 10% output loading, the output voltage will remain within data sheet specification however, output ripple and noise may increase but will still be below
150mV p-p.
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NCM6 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 5.2kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NCM6 series is pending recognition by Underwiters Laboratory for various voltages, please see safety approval section below.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on