4/ (FOLSVH3OXV 'DWD 6KHHW 5HY $
7DEOH 5$0 &HOO 6\QFKURQRXV $V\QFKURQRXV 5HDG 7LPLQJ
6\PERO
5$0 &HOO 6\QFKURQRXV 5HDG 7LPLQJ
3DUDPHWHU
tSRA
RA setup time to RCLK: time the READ ADDRESS must be stable before the active
edge of the READ CLOCK
tHRA
RA hold time to RCLK: time the READ ADDRESS must be stable after the active
edge of the READ CLOCK
tSRE
RE setup time to WCLK: time the READ ENABLE must be stable before the active
edge of the READ CLOCK
tHRE
RE hold time to WCLK: time the READ ENABLE must be stable after the active
edge of the READ CLOCK
tRCRD
RCLK to RD: time between the active READ CLOCK edge and the time when the
data is available at RD
5$0 &HOO $V\QFKURQRXV 5HDG 7LPLQJ
rPDRD
RA to RD: time between when the READ ADDRESS is input and when the DATA
is output
9DOXH
0LQ
0D[
0.686 ns
-
0 ns
-
0.243 ns
-
0 ns
-
-
4.38 ns
-
2.06 ns
RCLK
RA
RE
RD
tSRA
tHRA
tSRE
old data
tHRE
rPDRD
tRCRD
new data
)LJXUH 5$0 &HOO 6\QFKURQRXV $V\QFKURQRXV 5HDG 7LPLQJ
WWWWWW ZZZTXLFNORJLFFRP
4XLFN/RJLF &RUSRUDWLRQ