DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

V436532S04VATG-75 查看數據表(PDF) - Mosel Vitelic Corporation

零件编号
产品描述 (功能)
生产厂家
V436532S04VATG-75
Mosel-Vitelic
Mosel Vitelic Corporation  Mosel-Vitelic
V436532S04VATG-75 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MOSEL VITELIC
V436532S04VATG-75
Symbol
IO(L)
Parameter
Output leakage current
(DQ is disabled, 0V < VOUT < VCC)
Limit Values
Min.
Max.
40
40
Unit
µA
Capacitance
TA = 0°C to 70°C; VDD = 3.3V ± 0.3V, f = 1 MHz
Symbol
CI1
CI2
CICL
CI3
CI4
CIO
CSC
CSD
Parameter
Input Capacitance (A0 to A11, RAS, CAS, WE)
Input Capacitance (CS0-CS3)
Input Capacitance (CLK0-CLK3)
Input Capacitance (CKE0, CKE1)
Input Capacitance (DQM0-DQM7)
Input/Output Capacitance (I/O1-I/064)
Input Capacitance (SCL, SA0-2)
Input/Output Capacitance (SA0-SA2)
Limit Values
Max. 32M x 64
80
30
22
50
20
20
8
10
Unit
pF
pF
pF
pF
pF
pF
pF
pF
Operating Currents
TA = 0°C to 70°C, VCC = 3.3V ± 0.3V (Recommended operating conditions otherwise noted)
Max.
Symbol Parameter & Test Condition
-75
Unit
ICC1
Operating Current
tRC = tRCMIN., tRC = tCKMIN.
Active-precharge command cycling,
without Burst Operation
1 bank operation
1700
mA
ICC2P
ICC2PS
Precharge Standby Current in Power Down Mode
CS =VIH, CKEVIL(max)
ICC2N
ICC2NS
Precharge Standby Current in Non-Power Down Mode
CS =VIH, CKEVIL(max)
ICC3
ICC3P
No Operating Current
tCK = min, CS = VIH(min)
bank ; active state ( 4 banks)
tCK = min.
tCK = Infinity
tCK = min.
tCK = Infinity
CKE VIH(MIN.)
CKE VIL(MAX.)
(Power down mode)
60
mA
40
mA
400
mA
60
mA
700
mA
64
mA
ICC4
Burst Operating Current
tCK = min
Read/Write command cycling
1700
mA
Note
7
7
7
7,8
V436532S04VATG-75 Rev. 1.3 September 2001