DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

B25671A5287A375 查看數據表(PDF) - EPCOS AG

零件编号
产品描述 (功能)
生产厂家
B25671A5287A375 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
Power Capacitors
Power Factor Correction
B25671A5287A375
MKK525-D-25-P
Do not use HRC fuses to switch capacitors (risk of arcing).
Use thermal magnetic overcurrent relays for overload protection.
Resonance cases
Resonance cases must be avoided by appropriate application design in any case. Maximum total
RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be
exceeded.
Overtemperature
Exceeding maximum allowed temperature may set the safety device out of operation.
Overpressure Disconnector
To ensure full functionality of an overpressure disconnector, the following must be observed:
1. The elastic elements must not be hindered, i.e.
- connecting lines must be flexible leads (cables),
- there must be sufficient space (min. 5 cm) for expansion above the connections (see
“Clearing distance for overpressure disconnector”).
- folding beads must not be retained by clamps.
2. Maximum allowed fault current of 10000 A in accordance with UL 810 standard must be assured by
the application.
3. Stress parameters of the capacitor must be within the IEC60831 specification.
Re-switching vs. phase-opposition
In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phase-
opposition and resulting high inrush currents.
Vibration resistance
The resistance to vibration of capacitors corresponds to IEC 68, part 2–6.
Max. test conditions:
Test duration
2h
Frequency range 1
0 ... 55 Hz corresponding
to max. 0.7 g
Displacement amplitude 0.75 mm
These figures apply to the capacitor alone. Because the fixing and the terminals may influence the
vibration properties, it is necessary to check stability when a capacitor is built in and exposed to
vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude
reaches the maximum in strongly vibrating equipment.
Mechanical protection
The PoleCap capacitor has to be installed in a way that mechanical damages and dents in the
aluminum can are avoided.
FK PFC R&D
Please read the important notes,
cautions and warnings.
Page 6 of 8
2005-06-03

Share Link: 