CXA1853AQ
No.
Item
Symbol
Measurement conditions
Min. Typ. Max. Unit
Gamma black side
162 breakpoint difference
between R, G and B
∆PGBT
(See “Black Side Gamma Measurement Method”.)
Set V45 = VI, V23 = 1.6V, V68 = 5.0V and V77 = 3.3V.
Then measure the gamma breakpoints at TP15,
TP16 and TP17 and label the non-inverted side
as PGBRT, PGBGT and PGBBT, and the inverted
–0.15 0 0.15 V
side as PGBRTA, PGBGTA and PGBBTA, respectively.
∆PGBT = PGBRT (A) – PGBGT (A)
= PGBGT (A) – PGBBT (A)
= PGBBT (A) – PGBRT (A)
(See “Black Side Gamma Measurement Method”.)
R gamma black side
163 breakpoint sub adjustment ∆PGBR1
Set V45 = VI, V23 = 1.6V, V68 = 5.0V, V77 = 3.3V,
SW78 → ON and V78 = 1.6V.
Then measure the gamma breakpoint at TP15, and
0.15
0.3
—
V
range (1)
label the non-inverted side as PGBRN and the
inverted side as PGBRNA.
∆PGBR1 = PGBRN (A) – PGBGT (A)
R gamma black side
164 breakpoint sub adjustment ∆PGBR2
range (2)
Next, measure the gamma breakpoint at TP15 with
V78 = 5.0V, SW1 → ON and V1 = 4.0V, and label
the non-inverted side as PGBRM and the inverted
side as PGBMA.
— –0.3 –0.15 V
∆PGBR2 = PGBRM (A) – PGBGT (A)
(See “Black Side Gamma Measurement Method”.)
B gamma black side
165 breakpoint sub adjustment ∆PGBB1
Set V45 = VI, V23 = 1.6V, V68 = 5.0V, V77 = 3.3V,
SW79 → ON and V79 = 1.6V.
0.15 0.3
Then measure the gamma breakpoint at TP17, and
—
V
range (1)
label the non-inverted side as PGBBN and the
inverted side as PGBBNA.
∆PGBB1 = PGBBN (A) – PGBGT (A)
Next, measure the gamma breakpoint at TP17 with
B gamma black side
166 breakpoint sub adjustment ∆PGBB2
range (2)
V79 = 5.0V, SW1 → ON and V1 = 4.0V, and label —
the non-inverted side as PGBBM and the inverted side
as PGBBMA.
–0.3 –0.15
V
∆PGBB2 = PGBBM (A) – PGBGT (A)
Minimum RGB gamma
167 white side breakpoint value PGWN
(See “White Side Gamma Measurement Method”.)
Set V45 = VI, V23 = 1.6V, V71 = 5.0V, V74 = 5.0V,
SW41 → ON and V41 = 1.6V.
— –0.35 –0.05 V
Then measure the gamma breakpoints of the non-
inverted and inverted sides at TP15, TP16 and TP17.
(See “White Side Gamma Measurement Method”.)
Set V45 = VI, V23 = 1.6V, V71 = 5.0V, V74 = 1.6V,
Maximum RGB gamma
SW1 → ON, V1 = 2.3V, SW41 → ON and V41 =
168 white side breakpoint value PGWM
1.6V.
0.75 1.20 — V
Then measure the gamma breakpoints of the non-
inverted and inverted sides at TP15, TP16 and
TP17.
Gamma white side
169 breakpoint difference
between R, G and B
(See “White Side Gamma Measurement Method”.)
Set V45 = VI, V23 = 1.6V, V71 = 5.0V, V74 = 3.3V,
SW41 → ON and V41 = 1.6V.
Then measure the gamma breakpoints at TP15,
∆PGWT
TP16 and TP17 and label the non-inverted sides as
PGWRT, PGWGT and PGWBT, and the inverted sides –0.15 0
0.15
V
as PGWRTA, PGWGTA and PGWBTA, respectively.
∆PGWT = PGWRT (A) – PGWGT (A)
= PGWGT (A) – PGWBT (A)
= PGWBT (A) – PGWRT (A)
– 20 –