Maximum ratings
4
Maximum ratings
ST619LB
Table 3. Absolute maximum ratings
Symbol
Parameter
VI
VO
VSHDN
IO
TSTG
TOP
DC input voltage
Output voltage
Shutdown input voltage
Output current continuous
Storage temperature range
Operating junction temperature range
Value
Unit
-0.3 to 5.5
V
-0.3 to 5.5
V
-0.3 to (VI + 0.3)
V
120
mA
-55 to +150
°C
-40 to +85
°C
Note:
Absolute maximum ratings are those values beyond which damage to the device may occur.
Functional operation under these condition is not implied.
Table 4. Thermal data
Symbol
Parameter
RthJA
Thermal resistance junction-ambient (1)
1. This value depends from thermal design of PCB on which the device is mounted.
SO-8
160
Unit
°C/W
6/16