ADM1034
ADM1034 as before, but send only the data byte containing
the register. (See Figure 18.) A read operation is then
performed, using the serial bus address and the R/W bit set
to 1, followed by the data byte read from the data register.
(See Figure 19.)
However, if the APR is already at the desired address, data
can be read from the corresponding data register without
first writing to the APR. In this case, Figure 18 can be
omitted.
In Figure 17 to Figure 19, the serial bus address is
determined by the state of the LOCATION pin on powerup.
1
91
9
SCL
SDA
A6
START BY
MASTER
A5 A4 A3 A2 A1 A0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADM1034
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY
ADM1034
1
9
SCL (CONTINUED)
SDA (CONTINUED)
D7 D6 D5 D4 D3 D2 D1 D0
FRAME 3
DATA BYTE
ACK. BY STOP BY
ADM1034 MASTER
Figure 17. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
SCL
9
1
9
SDA
A6
START BY
MASTER
A5 A4 A3 A2 A1 A0
FRAME 1
SERIAL BUS ADDRESS BYTE
R/W
D7
ACK. BY
ADM1034
D6 D5 D4 D3 D2 D1 D0
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY STOP BY
ADM1034 MASTER
Figure 18. Writing to the Address Pointer Register Only (Send Byte)
1
9
1
9
SCL
SDA
A6
START BY
MASTER
A5 A4 A3 A2 A1 A0 R/W
D7 D6
FRAME 1
SERIAL BUS ADDRESS BYTE
ACK. BY
ADM1034
D5 D4 D3 D2 D1
FRAME 2
DATA BYTE FROM ADM1034
D0
NO ACK. BY STOP BY
ADM1034 MASTER
Figure 19. Reading Data from a Previously Selected Register
Register Addresses for Single/Block Byte Modes
The ADM1034 supports single byte as well as block read
and write operations. The register address determines
whether a single byte or multiple byte (block) operation is
run. For a single byte operation, the MSB of the register
address is set to 0; for a multiple byte operation, it is set to 1.
The number of bytes read in a multiple byte operation is set
in the #Bytes/Block Read Register at Address 0x00. The
number of bytes written to the ADM1034 is specified during
the block write operation. The addresses quoted in the
register map and throughout this data sheet assume single
byte operation. For multiple byte operations, set the MSB of
each register address to 1.
http://onsemi.com
11