ADM6384
Parameter
MANUAL RESET INPUT
MR Input Threshold
VIL
VIH
MR Input Pulse Width
MR Glitch Rejection
MR Pull-Up Resistance
MR to Reset Delay
RESET OUTPUT VOLTAGE
VOL
VOH
1 TA = 25°C only.
Min
Typ
Max
Unit
Test Conditions/Comments
0.7 × VCC
2.4
1
100
32
63
200
0.8 × VCC
0.8 × VCC
0.3 × VCC V
0.8
V
V
V
µs
ns
100
kV
ns
0.3
V
0.3
V
0.4
V
V
V
VCC < 4 V
VCC > 4 V
VCC < 4 V
VCC > 4 V
VCC ≥ 1.0 V, ISINK = 80 µA
VCC ≥ 2.5 V, ISINK = 1.2 mA
VCC ≥ 4.5 V, ISINK = 3.2 mA
VCC ≥ 2.5 V, ISOURCE = 500 µA
VCC ≥ 4.5 V, I SOURCE = 800 µA
Rev. C | Page 4 of 12