CXA1870S
Sub Address
1011
Sub Address
1100
Sub Address
1101
Sub Address
1110
G CUTOFF (4): G OUT cut-off voltage control
0 = Minimum
15 = Maximum
B CUTOFF (4): B OUT cut-off voltage control
0 = Minimum
15 = Maximum
H PHASE (4): Horizontal position control
0 = Screen shifted to right
15 = Screen shifted to left
V ON (1): VD output ON/OFF
0 = VD output stopped. (Picture mute applied simultaneously. Auto cut-off
reference pulse also muted.)
1 = VD output
V EX OFF (1): V sync elongation ON/OFF
0 = V sync elongation ON
1 = V sync elongation OFF
AFC (2): AFC loop gain switching
0 = AFC loop gain large
1 = AFC loop gain medium
2 = AFC loop gain small
3 = AFC loop open, free running mode
V SHIFT (5): Vertical position control
0 = Rise
31 = Lower
HV COMP (3): Vertical correction amount setting for high voltage fluctuations
0 = Correction amount minimum
7 = Correction amount maximum
V SIZE (6): Vertical amplitude control
0 = V size minimum
63 = V size maximum
C MODE (1): V countdown system mode switching
0 = Non-standard signal mode, standard signal mode and no signal mode
switched automatically.
1 = Fixed to non-standard signal mode (wide V sync window mode).
—35—