DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HI-6011 查看數據表(PDF) - Holt Integrated Circuits

零件编号
产品描述 (功能)
生产厂家
HI-6011 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
REGISTER DESCRIPTIONS
HI-6011
Control Word Register
Bits
0
1
2
3
4
5
7:6
Description
Reset Receiver 1.
Used to reset Receiver 1 at any time. Assert and remove a “1” to reset Receiver 1.
Note: Reset will destroy any word being received at the time of the reset.
“1” = reset. Reset must be removed to enable receiver. Receiver function inhibited by a high
level on reset.
Reset Receiver 2 – Same as for receiver 1.
Establish parity.
1 = ODD; 0 = EVEN. Both receivers and the transmitter must use the same parity.
Set Receiver 1 Data Rate: 0 = LOW (12-14.5 kbps); 1 = HIGH (100 kbps).
Set Receiver 2 Data Rate: Save as for Receiver 1.
Set Transmitter Data Rate.
Same as for Receiver 1.
Note: Data rates for the transmitter and individual receivers are independent.
Specifies Input Clock.
00 12 MHz
01 6 MHz
1x 1 MHz
Interrupt Status Register
Bits
0
1
2
3
4
5
6
7
Description
“1” = Receiver 1 has received word.
“1” = Receiver 1 word has a parity error.
“1” = Receiver 1 error (32 bits received before idle state).
“1” = Receiver 2 has received word.
“1” = Receiver 2 word has a parity error.
“1” = Receiver 2 error (32 bits received before idle state).
“1” = Transmitter buffer and FIFO entirely empty (Up to 5 words may be written to transmitter). .
“1” = Transmitter FIFO full. Do not write more words to transmit FIFO. (Words written while
this bit is set will be ignored). “0” = FIFO has room for at least 1 word.
HOLT INTEGRATED CIRCUITS
7

Share Link: 