FUNCTIONAL DEVICE OPERATION
PROTECTION AND DIAGNOSTIC FEATURES
Table 7. Functional Truth Table in Fault Mode
Conditions CONF INHS INLS OUT GLS FS
Over-temperature x
x
x
L
H
L
on OUT
Over-temperature x
x
x
L
L
L
on GLS
Over-current
x
H
L
L
x
L
on OUT
Overload
L
L
H
x
L
L
on External Low
Side MOSFET
H = High level
L = Low level
x = Don’t care
EN TEMP CSNS OCLS
Comments
H
L
x
x The 33981 is currently in Fault mode.
The OUT is OFF. TEMP at 0V
indicates this fault. Once the fault is
removed 33981 recovers its normal
mode.
H
L
x
x The 33981 is currently in Fault mode.
The OUT is OFF and GLS is at 0V.
TEMP at 0V indicates this fault. Once
the fault is removed 33981 recovers its
Normal Mode.
H
x
L
x The 33981 is currently in Fault mode.
The OUT is OFF. It is reset by a
logic [0] at INHS for at least tRST(DIAG).
When INHS goes to 0V, CSNS goes to
5.0 V.
H
x
x
L The 33981 is currently in Fault mode.
GLS is at 0 V and OCLS internal
current source is off. The external
resistance connected between OCLS
and GND pin will pull OCLS pin to 0V.
The fault is reset by a logic [0] at INLS
for at least tRST(DIAG).