EEPROM-Programmable, Quad,
Power-Supply Tracker/Sequencer Circuit
Table 3. Program Power-Down and Power-Up
REGISTER
ADDRESS
13h
0Ah
EEPROM MEMORY
ADDRESS
33h
2Ah
BIT RANGE
DESCRIPTION
[7:3]
[7:6]
[5:4]
Bit 7—If 1, reverse order of track/sequence power-down
If 0, GATE_ fast pulldown
Bit 6—If 1, OUT1 charges with internal pulldown
If 0, no pulldown is allowed
Bit 5—If 1, OUT2 charges with internal pulldown
If 0, no pulldown is allowed
Bit 4—If 1, OUT3 charges with internal pulldown
If 0, no pulldown is allowed
Bit 3—If 1, OUT4 charges with internal pulldown
If 0, no pulldown is allowed
“00” fault power-up timer value = 25ms
“01” fault power-up timer value = 50ms
“10” fault power-up timer value = 100ms
“11” fault power-up timer value = 200ms
“00” fault power-down timer value = 25ms
“01” fault power-down timer value = 50ms
“10” fault power-down timer value = 100ms
“11” fault power-down timer value = 200ms
Table 4. Setting the Slew Rate
REGISTER
ADDRESS
12h
EEPROM MEMORY
ADDRESS
32h
BIT RANGE
DESCRIPTION
Bit [7:6]
“00” track/sequence slew rate (rise or fall) = 800V/s
“01” track/sequence slew rate (rise or fall) = 400V/s
“10” track/sequence slew rate (rise or fall) = 200V/s
“11” track/sequence slew rate (rise or fall) = 100V/s
Inputs
IN1–IN4
The IN1–IN4 voltage detectors monitor voltages from
1V to 5.5V in 20mV increments, or +0.5V to +3.05V in
10mV increments. Use the following equations to set
the threshold voltages for IN_:
x = VTH - 1V
0.02V
for +1V to +5.5V range.
x = VTH - 0.5V
0.01V
for +0.5V to +3.05V range.
where VTH is the desired threshold voltage and x is the
decimal code for the desired threshold (Table 6). For
the +1V to +5.5V range, x must equal 225 or less; oth-
erwise, the threshold exceeds the maximum operating
voltage of IN1–IN4 (Table 6). An overvoltage or under-
voltage failure on an IN_ input immediately shuts down
all the OUT_ outputs and generates a FAULT in the
master/slave condition.
18 ______________________________________________________________________________________