DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

OR3C55 查看數據表(PDF) - Agere -> LSI Corporation

零件编号
产品描述 (功能)
生产厂家
OR3C55 Datasheet PDF : 210 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Data Sheet
June 1999
ORCA Series 3C and 3T FPGAs
Programmable Logic Cells (continued)
The ripple mode can be used in one of four submodes.
The first of these is adder-subtractor submode. In
this submode, each LUT generates three separate out-
puts. One of the three outputs selects whether the
carry-in is to be propagated to the carry-out of the cur-
rent LUT or if the carry-out needs to be generated. If
the carry-out needs to be generated, this is provided by
the second LUT output. The result of this selection is
placed on the carry-out signal, which is connected to
the next LUT carry-in or the COUT/FCOUT signal, if it
is the last LUT (K7/K3). Both of these outputs can be
any equation created from KZ[1] and KZ[0], but in this
case, they have been set to the propagate and gener-
ate functions.
The third LUT output creates the result bit for each LUT
output connected to F[7:0]/F[3:0]. If an adder/subtrac-
tor is needed, the control signal to select addition or
subtraction is input on ASWE, with a logic 0 indicating
subtraction and a logic 1 indicating addition. The result
bit is created in one-half of the LUT from a single bit
from each input bus KZ[1:0], along with the ripple input
bit.
The second submode is the counter submode (see
Figure 7). The present count, which may be initialized
via the PFU DIN inputs to the latches/FFs, is supplied
to input KZ[0], and then output F[7:0]/F[3:0] will either
be incremented by one for an up counter or decre-
mented by one for a down counter. If an up/down
counter is needed, the control signal to select the direc-
tion (up or down) is input on ASWE with a logic 1 indi-
cating an up counter and a logic 0 indicating a down
counter. Generally, the latches/FFs in the same PFU
are used to hold the present count value.
K7[0]
K6[0]
K5[0]
K4[0]
K3[0]
K2[0]
K1[0]
K0[0]
CIN/FCIN
C
DQ
C
K7
DQ
K6
DQ
K5
DQ
K4
DQ
K3
DQ
K2
DQ
K1
DQ
K0
DQ
REGCOUT
FCOUT
COUT
F7
Q7
F6
Q6
F5
Q5
F4
Q4
F3
Q3
F2
Q2
F1
Q1
F0
Q0
Figure 7. Counter Submode
5-5756(F)
Lucent Technologies Inc.
17